Technical Articles

Deep technical writing on pH, ORP, ISE, conductivity, ISO 17025 uncertainty, and applied electrochemistry across oil & gas, mining, water treatment, and food/ethanol processing. 14 articles.

ETAMunicipal WaterENMay 14, 2026

ORP in Chlorination for Canadian Water Utilities: Why Your Free Chlorine Reading Isn't What the Probe Says

Most Ontario and Quebec water operators use ORP as a proxy for free chlorine residual. At constant 1 mg/L Cl₂, ORP varies 130 mV between pH 6 and pH 9. That variation is a compliance risk under Ontari

ISO 17025CALA LabsENMay 12, 2026

Ion-Selective Electrodes for Copper, Chloride, and Nitrate: What CALA Labs Need to Know About Matrix Interference

An ISE is cheap, fast, and in certain matrices wildly wrong. On mining tailings, a copper ISE can read +42 % vs ICP-MS. Here is the matrix-by-matrix interference data, the slope-drift diagnostic, and

BiofuelsCorn EthanolENMay 10, 2026

Corn Ethanol Fermentation: Why 2 °C Outside the Window Costs a 75 MMgal Plant $340k a Month

US corn ethanol fermenters live in a 2 °C window. Outside it, Saccharomyces shifts to glycerol, or Lactobacillus infects. Field data from 12 Iowa/Nebraska plants — the pH/temperature architecture that

ETEFrigoríficoPT-BRMay 8, 2026

Eletrodos de pH em ETE de Frigorífico: Ataque Químico, Gordura e CIP

ETE de frigorífico combina os três piores agressores para eletrodos: gordura animal, CIP cáustico quente e cargas orgânicas de 2000 mg/L DBO. A sonda errada dura 6 semanas. A certa dura 11 meses.

MineríaLatAmESMay 6, 2026

Cianuración en Minería de Oro: Ventana de pH 10.5 y Control de CN⁻ Libre

En minería de oro LatAm, 0.3 pH fuera de la ventana 10.5–11.0 costa hasta USD 4M al año en recuperación perdida. La especiación HCN/CN⁻, la deriva del ISE en agua de mina, y la arquitectura que funcio

Sugar/EthanolFermentaçãoPT-BRMay 4, 2026

Fermentação de Etanol: Controle Térmico e pH no Biorreator Industrial

Na fermentação industrial de etanol, 2 °C fora da faixa reduzem rendimento em 8 %. pH abaixo de 3.5 inibe a levedura. Contaminação bacteriana só aparece no gráfico depois que o estrago está feito. Arq

ETAPotabilizaciónESMay 2, 2026

Control de ORP en Cloración de Plantas Potabilizadoras: Por qué su Residual no es lo que la Sonda Indica

El ORP en plantas potabilizadoras varía 130 mV para la misma concentración de cloro libre según el pH. Las sondas baratas no distinguen entre cloro activo y ORP alto. Datos, química y especificación c

ETELodo AtivadoPT-BRApril 30, 2026

Biofilme em Sondas de Condutividade em Lodo Ativado: O Erro de 15 % que Passa Despercebido

Em ETE industrial, o biofilme forma-se sobre sondas de condutividade em 30–45 dias e subestima o valor medido em até 15 %. Sem alarme, sem aviso. Dados de campo, tipos de sonda e estratégia de CIP que

ETAMunicipal WaterENApril 28, 2026

Chloride Interference in Municipal Water pH: What Canadian Auditors Miss Every Winter

Road-salt runoff pushes Calgary Bow River chloride to 3,800 mg/L every winter. Standard gel-junction electrodes read 1.0 pH low under that load. Here's what CSA B128 expects, and what low-maintenance

MiningCILENApril 26, 2026

Gold CIL pH Window and Free Cyanide Control: Where Your Recovery Actually Dies

The 0.3 pH drift that looks innocuous costs a 2,000 tpd gold operation roughly $140k per month in lost recovery. Here's the thermodynamics, the measurement architecture, and the control strategy — fro

ISO 17025CALA LabsENApril 24, 2026

ISO 17025 Junction Potential: The Non-Conformance Hiding in Your CALA Audit

Most CALA-accredited labs declare pH uncertainty that's missing the dominant term. Here's the junction-potential uncertainty budget that ISO 17025:2017 §6.5 actually expects — with sample matrix numbe

Oil & GasSAGDENApril 22, 2026

SAGD Produced Water pH: The Reference Electrode Architecture That Actually Survives

Standard Ag/AgCl references fail in 3–6 weeks in Athabasca SAGD produced water. Here's the architecture that delivers 10 months of stable operation — with field data at 50 ppm H₂S.

Oil & GasWastewaterENApril 15, 2026

Why Your pH Electrode Reads Wrong in H₂S Environments

Hydrogen sulphide poisons the Ag/AgCl reference and shifts junction potential. Full technical breakdown.

Sugar/EthanolENApril 12, 2026

Brix Interference on pH Measurement

Junction potential shift and reference contamination in high-Brix solutions — sugar, ethanol, and beverage labs.